Testing steps for First Alert, Kidde, X-Sense and Nest Protect, the levels a standard detector is built to alarm at, and where low-level detectors fit.

CPSC recommends testing CO detectors every month. Many manufacturers' manuals say to test weekly.

What the test button checks

Pressing the test button checks the detector's electronics and its horn. It doesn't make real carbon monoxide (First Alert). First Alert's manuals also say never to use an open flame to test.

Testing common brands

Models vary, so follow your own manual if it says something different.

  • First Alert: press and hold the Test/Silence button until the alarm sounds. On CO-only models like the CO605, you'll hear 4 beeps, a pause, then 4 beeps. First Alert's smoke/CO combination manuals say to hold the button for 3 to 5 seconds.
  • Kidde: press the Test/Reset button (some models need about 5 seconds). Models with a display usually show "---" and then "888" during the test. A Peak Level button shows the highest reading since the last reset. Kidde's manual notes that readings below 30 ppm can show on the display but won't set off the alarm.
  • X-Sense: press the Test/Silence button. A short beep means it has entered test mode.
  • Google Nest Protect: it runs a Self Test every 200 seconds and a Sound Check once a month, and you can run a full Safety Checkup from the app at any time. Google has stopped selling Nest Protect, so check when yours is due to be replaced.

Check the date

CDC says to replace your CO detector following the manufacturer's instructions or every 5 years. Most detectors also give an end-of-life chirp. Don't ignore it.

What a standard detector is built to alarm at

Most home CO detectors are listed to UL 2034. The standard sets alarm points based on both concentration and time:

CO level Must alarm within
70 ppm 60 to 240 minutes
150 ppm 10 to 50 minutes
400 ppm 4 to 15 minutes

Manuals for UL 2034 detectors also note that they're typically not built to detect CO below about 30 ppm. They're built to alarm at the time-based levels above.

Where low-level detectors fit

Some people want to know about lower CO levels too, especially homes with infants, older adults, someone who's pregnant or someone with heart disease. CPSC notes CO is especially toxic to those groups. Low-level detectors are built for that. Here's how two of them respond, next to what the UL 2034 standard requires. Response levels are from each manufacturer's specifications.

Defender LL6270 Low Level CO Monitor

CO level Defender LL6270 UL 2034 standard
5 to 8 ppm Reading shown on the display No reading or alarm required
9 to 14 ppm Red warning light within 10 minutes No alarm required
15 to 24 ppm Audible warning within 60 minutes No alarm required
25 to 49 ppm Audible and visual alarm within 30 minutes No alarm required
50 to 99 ppm Alarm within 15 minutes At 70 ppm: alarm within 60 to 240 minutes
100 to 149 ppm Alarm within 5 minutes At 70 ppm: alarm within 60 to 240 minutes
150 ppm or higher Immediate alarm At 150 ppm: 10 to 50 minutes. At 400 ppm: 4 to 15 minutes

See the Defender LL6270

CO Experts 2016 Low Level CO Monitor

CO level CO Experts 2016 UL 2034 standard
7 to 9 ppm Reading shown on the display No reading or alarm required
10 to 34 ppm Four beeps, once a minute No alarm required
35 to 50 ppm Four beeps, twice a minute No alarm required
Above 50 ppm Display reads "High", four beeps three times a minute At 70 ppm: 60 to 240 minutes. At 150 ppm: 10 to 50 minutes. At 400 ppm: 4 to 15 minutes

For the CO Experts 2016, the beep timing is how often the warning repeats, not how long it takes to start. See the CO Experts 2016

Low-level detectors like these are supplemental. They're not UL 2034 listed, so use them alongside the UL 2034 detectors your home or local code requires. If you want a UL 2034 listed detector with a display, the Defender CA6150 shows current CO from 10 ppm when you press the button and keeps a 30-day peak reading.

If your detector goes off

What to do depends on the kind of detector you have.

  • A standard CO detector (listed to UL 2034, the kind most homes have) is built to sound when CO reaches the alarm points in that standard, which start at 70 ppm over a period of time. If it goes off, get everyone outside to fresh air and call 911.
  • A low-level CO detector, like the Defender LL6270, warns at lower readings. Its red warning light can come on at 9 to 14 ppm. Follow the steps in its owner's manual for the reading on the display.
  • With any detector, if anyone has symptoms, get outside and call 911. CO poisoning can feel like the flu: headache, dizziness, nausea, confusion. People who are asleep can be overcome before they notice anything.

Ready to replace or add one?

Browse residential CO detectors or all CO detectors.

Sources: CPSC Carbon Monoxide Information Center; CDC: CO Poisoning Basics; UL 2034 alarm points as published in First Alert and BRK user manuals; Kidde, First Alert and X-Sense user manuals; Google Nest Help; Defender and CO Experts product specifications.