
Defender Carbon Monoxide Alarm & Low-Level Monitor Kit
Regular price $278.60In stock. Order before 2:00 PM PT (Mon–Fri) and it ships same day.
Why Choose Between a CO Alarm and a Low-Level Monitor?
Your home's carbon monoxide alarm serves an important purpose: warning you when CO exposure meets its programmed alarm conditions. But it doesn't necessarily tell you when smaller amounts of carbon monoxide are present.
The Defender CA6150 + LL6270 Carbon Monoxide Protection Kit gives you both capabilities in one package.
The CA6150 provides UL-listed residential alarm protection, while the LL6270 automatically displays carbon monoxide beginning at 5 parts per million (ppm) and provides additional visual and audible warnings at specified low-level thresholds.
Two separate devices. Two different functions. More information about the carbon monoxide in your home.
Both monitors operate independently, making this kit a practical choice for homeowners who want standard CO alarm protection alongside supplemental low-level monitoring.
What Makes This Defender Kit Different?
Most residential carbon monoxide alarms are designed to warn when CO concentrations and exposure durations meet established alarm-response requirements. They are not intended to provide continuous information about very low CO concentrations.
The Defender combination kit addresses two different needs: a listed residential alarm for conventional CO protection and a supplemental monitor for additional awareness of lower-level CO exposure.
- Residential alarm protection: The CA6150 is listed to ANSI/UL 2034 for residential carbon monoxide alarms.
- Automatic CO readings from 5 ppm: The LL6270 displays detected carbon monoxide without requiring a button press.
- Additional low-level warnings: The LL6270 provides a visual warning beginning at 9 ppm and an audible warning beginning at 15 ppm, subject to the manufacturer's response times.
- Digital information from both devices: Each includes a display and CO exposure memory functions.
- No routine battery changes: Both use factory-sealed lithium batteries.
- Two complementary devices: Use the CA6150 for listed residential alarm protection and the LL6270 for supplemental low-level monitoring.
Meet the Two Defender Monitors
Defender CA6150 — Residential Carbon Monoxide Alarm
The CA6150 is designed for homeowners who want a residential CO alarm with a digital display and long-life sealed batteries.
Its display button allows you to check detected CO concentrations beginning at 10 ppm. The alarm also records peak CO information and operates using factory-sealed lithium batteries designed for ten years of service.
The CA6150 is UL 2034 listed and follows residential alarm-response requirements based on both CO concentration and exposure duration.
Defender LL6270 — Supplemental Low-Level CO Monitor
The LL6270 provides a different kind of information. It automatically displays detected CO beginning at 5 ppm, helping you recognize lower concentrations that may not activate a conventional household alarm.
Its red visual warning begins at 9 ppm and its audible warning begins at 15 ppm, with activation times depending on the concentration and duration of exposure.
The LL6270 is intended as a supplemental low-level monitor. It is not UL listed as a residential carbon monoxide alarm and does not replace required residential CO alarms.
CA6150, LL6270 or the Kit?
The CA6150 is the alarm your home needs. The LL6270 tells you about low CO a standard alarm is designed to ignore. The kit gives you both.
Defender CA6150CO Alarm |
Defender LL6270Low-Level Monitor |
YOU'RE VIEWING
Defender KitCA6150 + LL6270
BEST PROTECTION
|
|
|---|---|---|---|
| What It Does | |||
| Main job | Required home CO alarm | Early warning at low CO levels | Both, in one order |
| UL 2034 listed home CO alarm | ✓ | — | ✓ |
| Shows CO on screen automatically | From 30 ppm | From 5 ppm | From 5 ppm |
| Check CO with a button press | From 10 ppm | Always on screen | Yes |
| Early warning light | — | From 9 ppm | From 9 ppm |
| Audible alarm | UL alarm levels (70 ppm within 1–4 hrs) | From 15 ppm | From 15 ppm |
| 85 dB alarm | ✓ | ✓ | ✓ |
| Peak CO memory and duration | 30 days | ✓ | ✓ |
| Power, Warranty and Shipping | |||
| Sealed lithium batteries, no battery changes | ✓ | ✓ | ✓ |
| Warranty | 10 years | 3 years | 10 + 3 years |
| Free shipping | Free | Free 2-day | Free 2-day |
| Best for | Meeting code: every level and outside sleeping areas | Knowing about low CO before a standard alarm would sound | Homes with a furnace, fireplace, water heater or gas range |
The LL6270 is a supplemental monitor. It is not UL listed as a residential CO alarm and does not replace the CO alarms your local code requires.
How Many Do You Need?
Short answer: at minimum, one CO alarm outside each sleeping area and one on every level of the home. The CA6150 in this kit is the UL 2034 listed alarm, so each of those locations needs a CA6150. Put the LL6270 where people sleep first, then add more if you want low-level warnings on other levels.
Typical homes:
- Single-story home, bedrooms down one hallway: 1
- Single-story home, bedrooms at opposite ends: 2
- Two-story home, bedrooms upstairs: 2 (upstairs hallway plus main level)
- Two-story home with a finished basement: 3
Add one inside any bedroom where someone sleeps with the door closed.
What the Manufacturers, Codes and Health Guidelines Say
| Defender (manufacturer) | At least one outside each sleeping area and one on every level of the home. Add one inside any bedroom where someone sleeps with the door closed. For the most complete coverage, Defender recommends detection in all rooms and areas of the home. |
|---|---|
| CO Experts (manufacturer) | If you have only one, install it in an occupied bedroom or in the hallway within 10 feet of all bedrooms. Recommends at least one low-level monitor on each level of the home. |
| International Residential Code (IRC R315) | Required in homes with a fuel-burning appliance or an attached garage. Install outside each separate sleeping area, near the bedrooms, and inside any bedroom that contains a fuel-burning appliance. |
| NFPA 72 (formerly NFPA 720) | Outside each sleeping area near the bedrooms, and on every occupiable level of the home, including basements. |
| U.S. Consumer Product Safety Commission | On each level of the home and outside sleeping areas. |
| UL 2034 | A product standard, not a placement rule. It sets how long a listed alarm waits before sounding: 70 ppm within 1 to 4 hours, 150 ppm within 10 to 50 minutes, 400 ppm within 4 to 15 minutes. |
| World Health Organization | Does not address placement. Its indoor air guidelines set exposure limits of about 9 ppm averaged over 8 hours and about 3.5 ppm over 24 hours, well below the levels that make a standard alarm sound. |
Bottom line: Every source agrees on the core: near the bedrooms and on every level. State and local codes can add requirements, such as hardwired or interconnected alarms in new construction, so check yours before you install.
Placement tips (Defender): mount about 5 feet off the floor or at eye level. Keep both devices more than 5 feet from cooking and fuel-burning appliances, out of garages, and at least 3 feet from bathrooms and laundry rooms.
Who Should Consider This Kit?
This kit is designed for homeowners who want more information about carbon monoxide than a conventional alarm alone provides.
It may be particularly useful in homes with fuel-burning furnaces, fireplaces, water heaters, or other combustion appliances, as well as households interested in monitoring lower concentrations of carbon monoxide.
Both devices are intended for indoor residential environments within their specified operating conditions. They are not designed for vehicles, RVs, or unconditioned spaces.
Where Should the Two Devices Be Installed?
Install the CA6150 outside the bedrooms, near the sleeping area, where its alarm will wake everyone.
Install the LL6270 where people sleep or spend the most time, so you see low-level readings before they become a problem.
The devices operate independently. They do not communicate with one another and do not provide wired or wireless interconnection.
Some jurisdictions require hardwired or interconnected CO alarms. Confirm local requirements before selecting a residential alarm installation.
Defender CO Protection Kit Specifications
| Included models | CA6150 and LL6270 |
|---|---|
| Number of devices | Two independent CO devices |
| Detection technology | Electrochemical CO sensors |
| CA6150 CO display | 10–999 ppm manually; 30–999 ppm automatically |
| LL6270 CO display | 5–500 ppm automatically |
| LL6270 visual warning | Beginning at 9 ppm |
| LL6270 audible warning | Beginning at 15 ppm |
| Power | Factory-sealed lithium batteries in each device |
| CA6150 warranty | 10-year limited warranty |
| LL6270 warranty | 3-year limited warranty |
| Operating temperature | 40–100°F |
| Operating humidity | 10–95% relative humidity |
| Dimensions, each | 5.5 × 3.75 × 1.375 inches |
| Installation | Indoor fixed mounting |
| Country of manufacture | Canada |
Frequently Asked Questions
Why would I need two carbon monoxide detectors?
The CA6150 provides listed residential CO alarm protection, while the LL6270 offers additional low-level readings and warnings. They perform different functions and can complement one another.
Does the LL6270 alarm at 5 ppm?
No. It automatically displays detected CO beginning at 5 ppm. Its visual warning begins at 9 ppm and its audible warning begins at 15 ppm, subject to response times.
Are both devices UL listed?
No. The CA6150 is UL 2034 listed as a residential CO alarm. The LL6270 is a supplemental low-level monitor and is not UL listed.
Are the two devices interconnected?
No. Each device operates independently with its own sensor, display, battery, and warning functions.
Do both devices last ten years?
No. The CA6150 is designed for a ten-year service life and has a ten-year limited warranty. The LL6270 has a three-year limited warranty. Defender identifies an expected service life of approximately five years for the LL6270, but recommends replacement every three years to maintain display accuracy as the sensor ages. Follow the manufacturer's replacement instructions.
Can I use this kit in an RV or motorhome?
No. These models are not designed for vehicles or unconditioned spaces. Select CO detection equipment approved for the intended environment.
Does the kit detect smoke or natural gas?
No. Both devices detect carbon monoxide only. They do not replace smoke alarms or combustible-gas detectors.
How many kits do I need for my home?
Most homes need one CO alarm outside each sleeping area and one on every level. A single-story home with one bedroom hallway usually needs one kit; a two-story home usually needs one kit for the sleeping level plus a CA6150 on the other level. See "How Many Do You Need?" above for what Defender, the codes and health guidelines say.
Safety reminder: Never assume an area is safe simply because a carbon monoxide alarm is silent. If an alarm activates or CO exposure is suspected, follow the manufacturer's emergency instructions and seek appropriate assistance.


